Customization: | Available |
---|---|
Classification: | Biological Diagnostics |
Type: | Biochemistry Analyzer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | DS-401 | DS-301 | DS-201 | DS-161 | |||
Operation | Random access | ||||||
Reading System | Direct reading system | ||||||
Method | End point, Kinetic, Fixed time, Immunoturbidimetric,1-2 reagent, Multistandard, reagent/serum blank,etc. | ||||||
Assay Item | 80 assay items+3 ISE items(optional) | 40 assay items+3 ISE items(optional) | 36 assay items+3 ISE items(optional) | ||||
Throughput | 1 Reagent | 400 tests/h | 300 tests/h (max) | 257 tests/h (max) | 220 tests/h (max) | ||
2 Reagent | 400 tests/h | 240 tests/h | 150 tests/h | 160 tests/h (max) | |||
With ISE | 400 tests/h | +150 tests/h | +150 tests/h | +100 tests/h | |||
Sample Position | 80 positions | 60 positions | 60 positions | 50 positions | |||
Including standard, control and stat; either serum cup or primary tube available | |||||||
Sample Volume | 1~100ul,0.1ul / step | ||||||
Reagent Position | 2 x 40 positions | 40 positions,or 80 positions(optional) | 36 positions | ||||
Reagent Volume | R1:1~400ul,1ul / step,R2:1~400ul,1ul / step | ||||||
Reagent / Sample Probe | With liquid level sensor, collision sensor, teflon coating and automatic washing | ||||||
Reaction Time | 0~999 seconds | ||||||
Cuvette | High quality uv-transmitted plastic cuvette or quartz glass cuvettes on request | ||||||
Washing | 8 channels automatic washing system for reaction cuvettes | 5 channels automatic washing system for reaction cuvettes | |||||
Independent washing station for each sample/reagent probe and mixer | |||||||
Alarm | Automatic alarm for malfunction (eg: collision, reagent / sample insufficiency, full waste container, etc) | ||||||
Calibration | Linear, Non-linear, Multi point, K factor | ||||||
Sample Dilution/Retest | Sample can be diluted and retested if results are out of range or sample is insufficient | ||||||
Wavelength | 340~810nm | ||||||
Light Source | Halogen lamp | ||||||
Absorbance Resolution | 0.0001A | ||||||
Absorbance Accuracy | ±0.0003A(0~2.5A) | ||||||
Repeatability (CV %) | ≤2% | ||||||
Quality Control | Levy Jennings quality control program at 3 levels at least | ||||||
Bar Code | Optional | ||||||
Printer | Multiple report formats available | ||||||
Other | Tele-diagnostic, bi-direction interface to LIS system, etc | ||||||
Language | English, French, Spanish, German, Russian, etc | ||||||
System | Windows XP or Vista ; Windows 7 | ||||||
Power Supply | 220V / 50Hz,or 110V / 60Hz(optional) | ||||||
Dimension | 100cm X 85cm X 70cm | 85cm X 72cm X 53cm | 85cm X 72cm X 53cm | 65cm X 53cm X 52cm | |||
Weight | 137Kg | 90Kg | 85Kg | 50Kg | |||